1 Stage Vacuum Pump
- 1 Stage Vacuum Pump
- One Stage Water Ring Vacuum Pump
- Description
-
One Stage Vacuum Pump is identified as HWVP-1.
The pump is used in the compression range of approx 150~250 Torrs under standard atmosphere. The pump is suitable to the application condition in which the suction value is more critical than the vacuum level.
Specification
Product | Exhaust Velocity (ℓ/min) | Pressure (at 15℃) Torr(Pa) |
RPM (r.p.m) |
Power (kW) |
Water Supply (ℓ/min) |
Suction (mm) |
Discharge (mm) |
Weight (kg) |
HWVP-1-2500 | 25000 | 50(6.7×103) | 1150 | 55(6P) | 85 | 8˝(200A) | 8˝(200A) | 1085 |
HWVP-1-3400 | 34000 | 50(6.7×103) | 1150 | 75(6P) | 95 | 8˝(200A) | 8˝(200A) | 1015 |
Outside View(Exterior View)
Product | Shaft Sealing |
A | B | C | D | E | F | G | H | I | J | K | L | M | N |
HWVP-1-2500 | M.S | 410 | 1190 | 200 | 545 | 825 | 1115 | 1515 | 345 | 40A | |||||
HWVP-1-3400 | 34000 | 1400 | 650 | 815 | 950 | 1350 | 410 | 1140 | 150 | 485 | 765 | 1115 | 1515 | 285 | 40A |